{"id":611,"date":"2021-12-28T09:29:42","date_gmt":"2021-12-28T01:29:42","guid":{"rendered":"https:\/\/showinhydro.com\/?p=611"},"modified":"2021-12-28T09:48:30","modified_gmt":"2021-12-28T01:48:30","slug":"analyse-des-defaillances-et-traitement-de-la-couche-de-renforcement","status":"publish","type":"post","link":"https:\/\/showinhydro.com\/fr\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/","title":{"rendered":"Analyse des d\u00e9faillances et traitement de la couche de renforcement"},"content":{"rendered":"

Corrosion du fil d'acier de la couche de renforcement<\/h2>\n\n\n\n

La principale raison de la corrosion du fil d'acier est la perte de l'effet protecteur de la couche ext\u00e9rieure de caoutchouc. L'utilisation de Tout d'abord, la couche ext\u00e9rieure de caoutchouc synth\u00e9tique n'est pas qualifi\u00e9e, et le caoutchouc ext\u00e9rieur est d\u00e9truit sous l'effet des conditions ext\u00e9rieures difficiles et du frottement du mat\u00e9riel, ce qui expose le fil d'acier et le fait rouiller. En outre, la taille du flambage de l'assemblage n'est pas raisonnable, ce qui laisse un espace apr\u00e8s le flambage, l'infiltration de l'eau de pluie ou d'autres fluides, ce qui entra\u00eene la rouille du fil d'acier \u00e0 long terme.<\/p>\n\n\n\n

Traitement : Si le fil d'acier rouille, le tuyau doit \u00eatre remplac\u00e9. Tuyau Lors de la s\u00e9lection du tuyau, il convient de choisir un tuyau r\u00e9sistant aux fluides et \u00e0 l'usure, tout en am\u00e9liorant les param\u00e8tres de conception et le processus de flambage, afin de s'assurer que les param\u00e8tres de flambage r\u00e9pondent aux exigences. Apr\u00e8s le flambage, le manchon et le fil d'acier mordent correctement, le flambage n'est pas en place ou le flambage est excessif L'assemblage du tuyau n'est pas qualifi\u00e9.<\/p>\n\n\n\n

Couche de renforcement Fil cass\u00e9<\/h2>\n\n\n\n

Deux raisons peuvent expliquer la rupture du fil dans la couche de renforcement : premi\u00e8rement, le manchon est soumis \u00e0 une pression trop \u00e9lev\u00e9e, ce qui entra\u00eene une force de cisaillement excessive du fil, facile \u00e0 cisailler sous l'action de la rupture de l'impulsion ; deuxi\u00e8mement, le tuyau est soumis \u00e0 une pression d'impact trop \u00e9lev\u00e9e, entre le manchon et le fil, il y a une traction fr\u00e9quente, ce qui entra\u00eene la rupture du fil.<\/p>\n\n\n\n

Traitement : en cas de rupture du fil, il convient de remplacer le tuyau ; si le tuyau est souvent soumis \u00e0 des chocs \u00e0 haute fr\u00e9quence, il convient, en fonction de la situation r\u00e9elle, de choisir plus de quatre couches de fil d'acier enroul\u00e9 comme couche de renforcement, tout en \u00e9vitant une pression de flambage excessive.<\/p>\n\n\n\n

Le fil d'acier que nous utilisons provient de la deuxi\u00e8me plus grande usine de fil d'acier d'Asie, de sorte que nos produits sont con\u00e7us pour \u00e9viter cette situation.<\/p>","protected":false},"excerpt":{"rendered":"

Corrosion of the reinforcing layer steel wire occurs The main reason for the corrosion of steel wire is the loss of the protective effect of the outer rubber layer. The use of First of all, the outer layer of synthetic rubber is not qualified, and the outer rubber is destroyed under the harsh external conditions […]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-611","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"\nFailure Analysis and Treatment of Reinforcement Layer - Xiuyuan Hydraulic Technology Co., Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/showinhydro.com\/fr\/connaissances\/analyse-des-defaillances-et-traitement-de-la-couche-de-renforcement\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Failure Analysis and Treatment of Reinforcement Layer\" \/>\n<meta property=\"og:description\" content=\"Corrosion of the reinforcing layer steel wire occurs The main reason for the corrosion of steel wire is the loss of the protective effect of the outer rubber layer. The use of First of all, the outer layer of synthetic rubber is not qualified, and the outer rubber is destroyed under the harsh external conditions […]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/showinhydro.com\/fr\/connaissances\/analyse-des-defaillances-et-traitement-de-la-couche-de-renforcement\/\" \/>\n<meta property=\"og:site_name\" content=\"Xiuyuan Hydraulic Technology Co., Ltd\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-28T01:29:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-28T01:48:30+00:00\" \/>\n<meta name=\"author\" content=\"Andrew Pan\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Andrew Pan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/\"},\"author\":{\"name\":\"Andrew Pan\",\"@id\":\"https:\/\/showinhydro.com\/#\/schema\/person\/57a6ce983af74f471ba78abef16ead16\"},\"headline\":\"Failure Analysis and Treatment of Reinforcement Layer\",\"datePublished\":\"2021-12-28T01:29:42+00:00\",\"dateModified\":\"2021-12-28T01:48:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/\"},\"wordCount\":306,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/showinhydro.com\/#organization\"},\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/\",\"url\":\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/\",\"name\":\"Failure Analysis and Treatment of Reinforcement Layer - Xiuyuan Hydraulic Technology Co., Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/showinhydro.com\/#website\"},\"datePublished\":\"2021-12-28T01:29:42+00:00\",\"dateModified\":\"2021-12-28T01:48:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/showinhydro.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Failure Analysis and Treatment of Reinforcement Layer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/showinhydro.com\/#website\",\"url\":\"https:\/\/showinhydro.com\/\",\"name\":\"Showin Hydraulics\",\"description\":\"China Leading Hydraulic Rubber Hoses Manufacturer\",\"publisher\":{\"@id\":\"https:\/\/showinhydro.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/showinhydro.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/showinhydro.com\/#organization\",\"name\":\"Showin Hydraulic Technology Co., Ltd\",\"url\":\"https:\/\/showinhydro.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/showinhydro.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/showinhydro.com\/wp-content\/uploads\/2023\/03\/New_Logo_2048_5121.png\",\"contentUrl\":\"https:\/\/showinhydro.com\/wp-content\/uploads\/2023\/03\/New_Logo_2048_5121.png\",\"width\":2560,\"height\":640,\"caption\":\"Showin Hydraulic Technology Co., Ltd\"},\"image\":{\"@id\":\"https:\/\/showinhydro.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/showinhydro.com\/#\/schema\/person\/57a6ce983af74f471ba78abef16ead16\",\"name\":\"Andrew Pan\",\"url\":\"https:\/\/showinhydro.com\/fr\/knowledge\/author\/402702666qq-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Analyse de d\u00e9faillance et traitement de la couche de renforcement - Xiuyuan Hydraulic Technology Co.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/showinhydro.com\/fr\/connaissances\/analyse-des-defaillances-et-traitement-de-la-couche-de-renforcement\/","og_locale":"fr_FR","og_type":"article","og_title":"Failure Analysis and Treatment of Reinforcement Layer","og_description":"Corrosion of the reinforcing layer steel wire occurs The main reason for the corrosion of steel wire is the loss of the protective effect of the outer rubber layer. The use of First of all, the outer layer of synthetic rubber is not qualified, and the outer rubber is destroyed under the harsh external conditions […]","og_url":"https:\/\/showinhydro.com\/fr\/connaissances\/analyse-des-defaillances-et-traitement-de-la-couche-de-renforcement\/","og_site_name":"Xiuyuan Hydraulic Technology Co., Ltd","article_published_time":"2021-12-28T01:29:42+00:00","article_modified_time":"2021-12-28T01:48:30+00:00","author":"Andrew Pan","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Andrew Pan","Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#article","isPartOf":{"@id":"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/"},"author":{"name":"Andrew Pan","@id":"https:\/\/showinhydro.com\/#\/schema\/person\/57a6ce983af74f471ba78abef16ead16"},"headline":"Failure Analysis and Treatment of Reinforcement Layer","datePublished":"2021-12-28T01:29:42+00:00","dateModified":"2021-12-28T01:48:30+00:00","mainEntityOfPage":{"@id":"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/"},"wordCount":306,"commentCount":0,"publisher":{"@id":"https:\/\/showinhydro.com\/#organization"},"articleSection":["Uncategorized"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/","url":"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/","name":"Analyse de d\u00e9faillance et traitement de la couche de renforcement - Xiuyuan Hydraulic Technology Co.","isPartOf":{"@id":"https:\/\/showinhydro.com\/#website"},"datePublished":"2021-12-28T01:29:42+00:00","dateModified":"2021-12-28T01:48:30+00:00","breadcrumb":{"@id":"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/showinhydro.com\/knowledge\/failure-analysis-and-treatment-of-reinforcement-layer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/showinhydro.com\/"},{"@type":"ListItem","position":2,"name":"Failure Analysis and Treatment of Reinforcement Layer"}]},{"@type":"WebSite","@id":"https:\/\/showinhydro.com\/#website","url":"https:\/\/showinhydro.com\/","name":"Showin Hydraulics","description":"Fabricant leader de tuyaux hydrauliques en caoutchouc en Chine","publisher":{"@id":"https:\/\/showinhydro.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/showinhydro.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/showinhydro.com\/#organization","name":"Showin Hydraulic Technology Co.","url":"https:\/\/showinhydro.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/showinhydro.com\/#\/schema\/logo\/image\/","url":"https:\/\/showinhydro.com\/wp-content\/uploads\/2023\/03\/New_Logo_2048_5121.png","contentUrl":"https:\/\/showinhydro.com\/wp-content\/uploads\/2023\/03\/New_Logo_2048_5121.png","width":2560,"height":640,"caption":"Showin Hydraulic Technology Co., Ltd"},"image":{"@id":"https:\/\/showinhydro.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/showinhydro.com\/#\/schema\/person\/57a6ce983af74f471ba78abef16ead16","name":"Andrew Pan","url":"https:\/\/showinhydro.com\/fr\/knowledge\/author\/402702666qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/posts\/611","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/comments?post=611"}],"version-history":[{"count":0,"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/posts\/611\/revisions"}],"wp:attachment":[{"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/media?parent=611"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/categories?post=611"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/showinhydro.com\/fr\/wp-json\/wp\/v2\/tags?post=611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}